Legislation Details

File #: 26-1822    Name:
Type: Public Hearings Status: Agenda Ready
File created: 11/16/2026 In control: Planning Commission
On agenda: 11/19/2026 Final action:
Title: Public hearing, consideration, and possible action regarding PUD-003080-2026 (Planned Unit Development), Florence Estates, 9.25 acres, AG (Agricultural) to AG/PUD-003080-2026, located on the southwest corner of Florence Street (111th Street) and 9th Street (Lynn Lane Road / 177th E Avenue)
Attachments: 1. 2-Case Map, 2. 3-Comprehensive Plan Map, 3. 4-Aerial Map, 4. 5-Florence Estates PUD Document
Date Action ByActionResultAction DetailsMeeting DetailsVideo
No records to display.

Broken Arrow Planning Commission

11-19-2026

 

To:                     Chairman and Commission Members

From:                     Community Development Department

Title: 

title

Public hearing, consideration, and possible action regarding PUD-003080-2026 (Planned Unit Development), Florence Estates, 9.25 acres, AG (Agricultural) to AG/PUD-003080-2026, located on the southwest corner of Florence Street (111th Street) and 9th Street (Lynn Lane Road / 177th E Avenue)

End

Background:

Applicant:                                          Erik Enyart, Tanner Consulting

Owner:                     Timee Michelle Myers & Joe Hillenburg, & Candis Suzanne Hancock Trust

Developer:                                          N/A

Engineer:                                          Tanner Consulting

Location:                                          At the southwest corner of Florence Street (111th Street) and 9th Street
(Lynn Lane Road / 177th E Avenue)

Size of Tract                                          9.25 acres (402,930 square feet)

Number of Lots:                     1 lot

Present Zoning:                     AG (Agricultural) to AG/PUD-003080-2026

Comp Plan:                                          Level 4 and Greenway/Floodplain to Level 1 (Rural Residential) and         Greenway/Floodplain via COMP-003078-2026

 

PUD-003080-2026 is a request for approval of a Planned Unit Development permit for 9.25-acre property that is currently unplatted. The property is located at the southwest corner of Florence Street (111th Street) and 9th Street (177th East Avenue / Lynn Lane Road).

 

The property owner recently requested a Comprehensive Plan Amendment (COMP-003078-2026) to change the Future Land Use Designation of the property from Level 4 and Greenway/Floodplain to Level 1 and Greenway Floodplain. The Planning Commission recommended approval (4-1 vote) of this request at their November 5, 2026, meeting. No citizens spoke in favor or in opposition to the request that is scheduled for consideration by the City Council at their November 16, 2026, meeting. Level 1 is in conformance with the existing Agricultural zoning.

 

The buyer of the property intends to split this property into two large residential lots. Each lot is proposed to include one single-family residence. After dedicating approximately 1.669 acres for right-of-way along Florence Street and S. 9th Street, the remaining lot area will be 7.581 acres. The minimum lot area in the Agricultural district is five (5) acres, and the minimum lot frontage is 330 feet. Splitting the property into two lots will allow for a minimum of 3.5 acres per lot.

 

Several properties in the vicinity have been developed with large-lot, single-family residences, so this request is in conformance with several nearby properties. However, to do so with the existing Agricultural zoning, the resulting lots will not meet the minimum lot area of five acres. The applicant a minimum lot size of 3.5 acres in the PUD.

 

One of the excluded uses in the PUD is agriculture. Staff is not in support of maintaining Agricultural zoning but excluding agriculture as an allowed use. Staff recommends that the exclusion of an agricultural use be struck from the PUD document.

 

SURROUNDING LAND USES/ZONING/COMPREHENSIVE PLAN

 

The surrounding properties contain the following Planned Unit Development permit future development guide and zoning designations, as well as the existing land uses:

 

Location

Comprehensive Plan

Zoning

Land Use

North

Levels 2 and 4

CG and RS-3/ PUD-000197-2022

Single-Family Residential Under construction, undeveloped commercial lot

East

Level 2 and Greenway/Floodplain

A-1

Single-Family Residential and vacant

South

Level 3 and Greenway/Floodplain

A-1

Single-Family Residential

West

Level 3

A-1

Large Lot Single-Family

SUMMARY OF DEVIATION FROM THE BROKEN ARROW ZONING ORDINANCE

 

​Item

​Zoning Ordinance Requirement for AG

​PUD-003080-2026 Request

​Permitted Uses

​× Uses permitted by right within the AG district and uses customarily accessory to the specified uses; × or uses that may be conditionally allowed with approval of a Specific Use Permit in the AG district.

× As permitted in the AG District and uses customarily accessory to the specified allowed uses; accessory buildings in aggregate shall not occupy more than 50% of the building square footage associated with the principal use but are otherwise not restricted in individual size; × Excluded uses: agriculture, group homes, municipal or community recreation, public safety facility, community playfields and parks, and golf course or driving range (lighted and unlighted)

 

​Item

​Zoning Ordinance Requirement for AG

​PUD-003080-2026 Request

Maximum Number of Lots

1 lot for every 5 acres with 330 feet of lot frontage

2

Minimum Street Frontage

330 feet

50 feet

Minimum Lot Width

N/A

230 feet

Minimum Lot Area

5 acres

3.5 acres

Minimum Gross Land Area per Dwelling Unit

Gross land area    = Permitted Minimum area       number of per lot                    units

5 acres

Maximum Building Height

50 feet

3 stories and 35 feet

Lot Coverage

30 %

30 %

Minimum Livable Open Space per Dwelling Unit

N/A - does not apply to AG

106,722 square feet

Setbacks

Front - 50 feet Rear  - 50 feet Side - Interior lots - 25 feet (one side), 60 feet both sides combined - Adjacent to Arterial - 50 feet - Adjacent to Non-Arterial Public Street/Alley - 50 feet

Front - 50 feet Rear - 50 feet or 20% of the lot depth Side - Interior - per zoning ordinance - Adjacent to Arterial - per zoning ordinance - Adjacent to Non-Arterial Public Street/Alley - per zoning ordinance

Minimum Landscaping Tree Requirements

Per Section 4-3-6.B.1 of the Zoning Ordinance

3 large trees in front yards

Other Bulk Area Requirements

As required within the AG District and a PUD District

 

According to Section 6-3-4.3.A of the Zoning Ordinance, the PUD provisions are established for one (1) or more of the following purposes:

 

1.                     To permit and encourage innovative land development while maintaining appropriate limitation on the character and intensity of use and assuring compatibility with adjoining and proximate properties.

2.                     To permit greater flexibility within the development to best utilize the physical features of the particular site in exchange for greater public benefits than would otherwise be achieved through development under this Ordinance.

 

3.                     To encourage the provision and preservation of meaningful open space.

 

4.                     To encourage integrated and unified design and function of the various uses comprising the planned unit development.

 

5.                     To encourage a more productive use of land consistent with the public objectives and standards of accessibility, safety, infrastructure and land use compatibility.

 

In Staff’s opinion, PUD-003080-2026 satisfies items 1 and 3 of Section 6-3-4.3 of the Zoning Ordinance. (1) By limiting the development of the site to two lots, each with a single-family residence, will maintain the character of the adjacent large lot properties in the area (3) The PUD limitation of lot coverage to 30 percent will ensure the preservation of meaningful open space on the site.

 

According to FEMA Maps, a portion of this property is located within the 100-year floodplain. Water and Sanitary Sewer are available from the City of Broken Arrow.

 

Attachments:                        Case Map
                                    Comprehensive Plan Map
                           Aerial Map
                           Florence Estates PUD Document                     

 

Recommendation:                      

Based on the location of the property and surrounding land uses, Staff recommends PUD-003080-2026 be approved, subject to the property being platted.

 

Reviewed by:  Jane Wyrick

Approved by:  Rocky Henkel

JMW